The multi-channel peptide synthesizer is an important equipment used in biotechnology and pharmaceutical industry, mainly for synthesizing various peptides. However, due to its complex operating process and precise instrument structure, some malfunctions may occur during use.
Common malfunctions and solutions of multi-channel peptide synthesizer instruments:
Firstly, one of the most common malfunctions is that the device cannot start. This may be caused by power supply issues, wiring issues, or internal equipment malfunctions. The solution is to first check if the power supply is normal, and then check if the power cord and interface of the device are damaged or loose. If there are no issues with these, it may be an internal issue with the equipment that requires professional maintenance personnel to inspect and repair.
Secondly, there may be unstable temperature control during the operation of the equipment. This may be caused by temperature sensor failure, heating element failure, or temperature control system failure. The solution is to first check if the temperature sensor is working properly, and then check if the heating element is damaged or aged. If there are no issues with these, it may be a problem with the temperature control system, which requires professional maintenance personnel to inspect and repair.
Once again, there may be unstable pressure control during the operation of the equipment. This may be caused by a malfunction in the pressure sensor, pressure regulating valve, or pressure control system. The solution is to first check if the pressure sensor is working properly, and then check if the pressure regulating valve is damaged or aged. If there are no issues with these, it may be a problem with the pressure control system that requires professional maintenance personnel to inspect and repair.
In addition, the multi-channel peptide synthesizer equipment may experience uneven solution mixing during operation. This may be caused by malfunctions in the agitator, solution pump, or solution mixing system. The solution is to first check if the agitator is working properly, and then check if the solution pump is damaged or aged. If there are no issues with these, it may be a problem with the solution mixing system, which requires professional maintenance personnel to inspect and repair.
Finally, there may be excessive noise during the operation of the equipment. This may be caused by wear, looseness, or damage to the mechanical components inside the equipment. The solution is to first inspect the mechanical components inside the equipment for wear, looseness, or damage, and then make necessary replacements or repairs.